Fire Damper

Critical Fire Safety Components for HVAC Ductwork Systems

HOME > Fire Damper
Fire Damper Installation
FIRE & SMOKE CONTAINMENT SYSTEMS

Fire Damper

Fire Dampers are critical safety devices installed in HVAC ductwork to prevent the spread of fire and smoke through ventilation systems. They automatically close when triggered by heat or smoke detection systems, compartmentalizing fire zones and protecting life and property.

Product Specification

Technical Specifications

Fresh Air, Return Air & Exhaust Air dampers shall be opposed blade type and made from aluminum extruded section, bearing mounted suitable for automatic controls and casing shall be of box type made of thick M.S. plate and shall be fitted with non-ageing gaskets.

Key Design Features:
  • Blade Type: Opposed blade configuration for superior airflow control
  • Material: Aluminum extruded sections with bearing mounts
  • Casing: Box type constructed from thick M.S. plate
  • Sealing: Non-ageing gaskets for long-term performance
  • Controls: Compatible with automatic control systems

Technical Specifications

Parameter Specification Details
Type Dynamic Fire Damper Opposed blade design
Material - Blades Aluminum Extruded Section Lightweight & corrosion resistant
Material - Casing Thick M.S. Plate Box type construction
Mounting Bearing Mounted Smooth operation & durability
Control Compatibility Automatic Control Systems BMS & fire alarm integration
Sealing Non-ageing Gaskets Long-lasting smoke seal
Fire Rating 1-2 Hours (Standard) Tested to ASTM/UL standards
Temperature Rating Up to 350°F (177°C) High temperature operation

Types of Fire Dampers

Static Fire Damper

Operation:

  • Fusible link activated
  • Spring-loaded closure
  • No power required
  • Mechanical operation

Applications: General building compartments

Dynamic Fire Damper

Operation:

  • Opposed blade design
  • Motorized operation
  • Airflow maintained
  • Automatic control

Applications: HVAC systems with airflow

Smoke Damper

Operation:

  • Smoke detection
  • Early warning closure
  • Seals smoke passage
  • Fire alarm integrated

Applications: Smoke control systems

Construction Details

Blade Assembly
  • Opposed blade configuration
  • Aluminum extruded sections
  • Precision bearing mounts
  • Corrosion-resistant finish
  • Low friction operation
  • Thermal expansion compensation
Casing Structure
  • Box type construction
  • Thick M.S. plate material
  • Reinforced corners
  • Flanged connections
  • Fire-rated insulation
  • Powder coated finish
Sealing System
  • Non-ageing gaskets
  • Intumescent strips
  • Multi-point sealing
  • Smoke-tight closure
  • High temperature resistant
  • Maintenance-free design
Control System
  • Automatic activation
  • Manual override
  • Position indication
  • BMS integration
  • Fail-safe operation
  • Remote monitoring

Applications

Commercial Buildings
  • Office towers
  • Shopping malls
  • Hotels & Resorts
  • Hospitals
  • Educational institutions
  • Government buildings
Industrial Facilities
  • Manufacturing plants
  • Warehouses
  • Power plants
  • Chemical plants
  • Oil & gas facilities
  • Pharmaceutical units
Public Infrastructure
  • Airports
  • Railway stations
  • Metro stations
  • Theaters & Auditoriums
  • Sports stadiums
  • Convention centers

Installation Requirements

Physical Installation
  • Mounted in fire-rated walls/ceilings
  • Proper alignment with ductwork
  • Adequate access for maintenance
  • Fire-rated sealants around perimeter
  • Support framing as per specifications
  • Clearance for blade operation
Electrical Integration
  • Connection to fire alarm system
  • Integration with BMS
  • Power supply requirements
  • Control wiring specifications
  • Testing and commissioning
  • Documentation and certification
1